Who's Online
There currently are 6043 guests online.
|
Categories
|
Information
|
Featured Product
|
|
|
|
|
There are currently no product reviews.
;
Very good service Within one day i received a pdf of the users manual and electric circuits so I was able to measure the different voltages in the printed circuit and find out the fault Payment was also reliable and easy.Without the manual i could not have repaired.So thanks to "Search for a manual"
;
you are doing great job guys.....my father ask me to find out the schematics of Sony KV25R1D to sort out the problem ..(he was electrical technician, and excperianced with TV and simillar stuff). finally he found the cause and change all necessary parts....now he has got working old dog..and is very happy!!... thank you all.. NB..he also saved the repair cost.
;
Perfect. Received my manual within 24 hours. Clear scan of the manual I needed. No problem.
;
Item as described, very well detailed manual with complete schematics. I've received the download information shortly after payment, very good support.
;
Really good and well scanned. File is complete the full service manual for 5$
8. SERVICE PROCEDURE
MICRO-COMPUTER
To check the microcomputer firmware version, press 6.1 CH IN button and SLEEP button simultaneously while
2-2. AM(MW) Alignment Output of signal generator should not be greater than necessary to obtain an optimum output reading. Signal generator modulation ................................................................. 30% Signal frequency ................................................................................ 400Hz Modulation frequency ........................................... 603, 999, 1404kHz (/A/K/N) Modulation frequency ............................................ 600, 1000, 1400kHz (/U) Switch ........................................................... press the BAND Button to AM
power is on. The version number is shown on the main display of the unit. Ex. V 020716 01
TUNER 1. Requried Equipments
- AM Standard Signal Generator (AM SSG) - Oscilloscope - AC Voltmeter - FM Standard Signal Generator (FM SSG) - Stereo Modulator - Audio Generator - Distortion Meter - DC Voltmeter - Frequency Counter
Step 1
Subject Tunning voltage
Signal generator setting 522kHz (/A/K/N) 520kHz (/U) 603kHz (/A/K/N) 600kHz (/U)
Set frequency setting 522kHz (/A/K/N) 520kHz (/U) 603kHz (/A/K/N) 600kHz (/U) 603kHz (/A/K/N) 600kHz (/U) 999kHz (/A/K/N) 1000kHz (/U)
Equipment connection DC voltmeter
Adjustment point RF BLOCK OSC coil
Adjust for 522 kHz : 1.0 ~ 1.3V 1611 kHz : 7.0 ~ 8.5V
2
Note : Disconnect external FM antenna prior to alignment.
IF Tracking
AC voltmeter oscilloscope tape monitor L/R AC voltmeter oscilloscope tape monitor L/R AC voltmeter oscilloscope tape monitor L/R
IF BLOCK Coil KSNT-111I
Maximize audio output
2. Alignment
2-1. Alignment Test Points
3
RF Tracking
603kHz (/A/K/N) 600kHz (/U)
RF BLOCK ANT coil
Maximize audio output Repeat LOW, HIGH frequency
4
Seek level
999kHz (/A/K/N) 1000kHz (/U)
SVR 03
Tuned on point
2-3. LW Alignment (/A/N) Output of signal generator should not be greater than necessary to obtain an optimum output reading. Signal generator modulation ................................................................. 30% Signal frequency ................................................................................ 400Hz Modulation frequency ....................................................... 162, 207, 252kHz Switch ........................................................... press the BAND Button to LW
Step 1
Subject Tunning voltage
Signal generator setting 152kHz
Set frequency setting 152kHz
Equipment connection DC voltmeter
Adjustment point RF BLOCK OSC coil
Adjust for 522 kHz : 1.5 ~ 2.3V 1611 kHz : 6.0 ~ 7.5V
2
RF Tracking
162kHz
162kHz
AC voltmeter oscilloscope tape monitor L/R AC voltmeter oscilloscope tape monitor L/R
RF BLOCK ANT coil
Maximize audio output Repeat LOW, HIGH frequency
3
Seek level
207kHz
207kHz
Tuned on point
59